IO terminal function
user customization function
suitable for HD700 drives
the User software version is V2.03 and above
IO terminal function: HDOM-IO-Logic has three digital input terminals, an analogue input terminal, two relay output terminals, a digital output terminal, an analogue output terminal and two encoder input terminals. All these terminals can be programmed by the user. HDOM-IO-Logic can provide DC 5V/24V or 10V power supply.
User customization function: HDIAC can develop exclusive application solutions and built in HDOM-IO-Logic for the user. The user can make the HD700 drive as a special drive with customized HDOM-IO-Logic, so as to effectively reduce the user’s cost.
Specifications:
Type |
Terminal name |
Technical specifications |
---|---|---|
Digital input terminals |
X1, X2, X3 |
The common is 0V, input resistance:10K High, low logic threshold: 10V Sampling period: 400ms/1ms |
Digital output terminal |
DO |
Output voltage: 24V Maximum output current: 50mA Updating rate: 400ms/20ms |
Relay output terminals |
TA, TB |
Contact rating: 250VAC/2A (cosφ=1) 250VAC/1A (cosφ=0.4) 30VDC/1A Normally closed Updating rate: 400ms/5ms |
Analogue input/output terminal |
AI |
010V, input resistance: 100K 0(4)mA20mA, load resistance: 188Ω Resolution: 0.1%, Accuracy: 2% Sampling period: 400ms/5ms |
AO |
010V, maximum output current: 10mA Resolution:0.4%, Accuracy: ±5% 020mA/200mA/420mA/204mA, Accuracy: 1%, Updating rate: 400ms/5ms |
|
Power supply reference |
0V |
|
10V |
Accuracy: 2%, Maximum output current: 10mA |
|
+P |
The common can be 5V or 24V by setting the P09.31 (the default is 5V). Maximum output current: 100mA |
|
Encoder input terminal |
EA, EB |
Support 5V/24V voltage mode or open collector signal, only for Quadrature Encoder. |